Quote within 24 hours
UL · ISO 9001 · CE · RoHSquote@hareca.com.cn
Drive-to-motor connections

VFD cables.

Shielded power cables for variable frequency drive systems.

HAR&CA VFD cable constructions with branded sheaths
HAR&CA cable range

Power. Control.
A reliable connection.

Range12 constructions
Working voltage*600 V
InsulationXLPE / XLPO
Outer jacketPVC
Browse the range ↓

*As stated in the supplied specifications; subject to final approval.

The application

Between the drive
and the motor.

A variable frequency drive adjusts an electric motor’s speed. The cable carries power from the drive to the motor.

Rapid switching creates electrical noise and voltage stress. Cable insulation, shielding and grounding must suit the drive system.

Typical VFD applications include pumps, fans, conveyors and machine tools. Cable suitability depends on the installation.

The range

Find your construction.

HAR&CA codePower + ground / mm²InsulationShieldingEnquiry
H-RGD012-3C3G0163 × 3.3 mm² power + 3 × 1.31 mm² groundXLPECopper tapeEnquire ↗
H-RGD010-3C3G0143 × 6 mm² power + 3 × 2.08 mm² groundXLPECopper tapeEnquire ↗
H-RGD006-3C3G0123 × 13.3 mm² power + 3 × 3.3 mm² groundXLPECopper tapeEnquire ↗
H-RGD004-3C3G0123 × 21.2 mm² power + 3 × 3.3 mm² groundXLPECopper tapeEnquire ↗
H-RGD002-3C3G0103 × 35 mm² power + 3 × 6 mm² groundXLPECopper tapeEnquire ↗
H-RGD001-3C3G0103 × 50 mm² power + 3 × 6 mm² groundXLPECopper tapeEnquire ↗
H-RGD1-0-3C3G0103 × 53.5 mm² power + 3 × 6 mm² groundXLPECopper tapeEnquire ↗
H-RGD2-0-3C3G0103 × 70 mm² power + 3 × 6 mm² groundXLPECopper tapeEnquire ↗
H-RGD3-0-3C3G0083 × 95 mm² power + 3 × 8.4 mm² groundXLPECopper tapeEnquire ↗
H-RGD006-4C4G0144 × 16 mm² power + 4 × 2.5 mm² groundXLPOTape + tinned copper braidEnquire ↗
H-RGD004-4C4G0144 × 25 mm² power + 4 × 2.5 mm² groundXLPOTape + tinned copper braidEnquire ↗
H-RGD002-4C4G0124 × 35 mm² power + 4 × 4 mm² groundXLPOTape + tinned copper braidEnquire ↗

Metric sizes shown as supplied. Final sizes and construction require confirmation.

Engineering information

Two construction groups.

3 power + 3 ground conductors

InsulationXLPE

ShieldingCopper tape

ConductorBare copper, Class 5

Outer jacketPVC

4 power + 4 ground conductors

InsulationXLPO

ShieldingAluminium / polyester / aluminium tape with tinned copper braid

ConductorBare copper, Class 5

Outer jacketPVC

Procurement

Specify your requirement.

Send the product code, total quantity, cut lengths and required delivery date.

Include drive voltage, motor details, cable run length and installation conditions.